EZ-TILT-6000
with
VIB-NULL-C29
APPLICATION
MANUAL
Limited
Warranty:
The seller warrants that its product will be free of
defect in material and workmanship for a period of ninety (90) days from date of
shipment thereof. Within the warranty period the seller will, at its option,
either repair or replace such product which is determined by the seller to be
defective and which is returned with shipping charges prepaid.
This warranty will not apply to any product which has been subjected to
misuse, negligence or accident; or misapplied; or modified or repaired by
unauthorized persons; or improperly installed; or altered in any way.
This warranty is not applicable to resale products.
THIS LIMITED
WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OR IMPLIED, INCLUDING
THE WARRANTY OF MERCHANTABILITY OF FITNESS FOR PARTICULAR PURPOSE.
Company
profile.
Advanced Orientation Systems, Inc. (AOSI) was founded
in January of 1995 with a goal of developing and producing the next generation
of tilt sensors. AOSI quickly became an integral part of the angle measurement
industry.
EZ-TILT-6000
PORT POWERED RS-232 or USB EZ-TILT-6000, advanced
programmable dual/single axis LINEAR Digital output tilt module, built around a
customized state of the art CMOS Microprocessor.
The module is equipped with full range linearity correction routine for
each axis of tilt.
The standard module uses any two sensor combination of either SX-xxxD-LIN, SX-003D-NULL, SX-xxxD-VIB or SX-COMBO single axis inclination sensors and provides an economical and reliable tilt sensing solution for applications requiring superior Nulling capabilities with concurrent excellent Mid-Wide range LINEARITY, resolution, repeatability and symmetry. Rugged hermetic construction and MIL-SPEC temperature range make these sensors perfectly suitable for numerous high precision OEM, military, medical, optical, automotive, range finder, alignment, automation, robotics and construction angle measurement applications.
EZ-TILT-6000 is available with all AOSI ceramic tilt sensors.
ATTRIBUTE
SX-C29
SX-003-NULL
SX-003-NULL-L SX-005-VIB
SX-015-VIB
units
RANGE (max)
+-4
+-3
+-4
+-5
+-15
arcdeg
RESOLUTION
<0.002
<0.002
<0.004
<0.006
<0.008
arcdeg
LINEARITY
<0.3%@4
<0.5%@1
<0.3%@2
<0.2%@5
<0.3%@12
%FS
LINEARITY
<0.2%@1
<0.4%@0.5
<0.2%@1
<0.1%@3
<0.07%@5
%FS
SYMMETRY
<0.2
<0.2
<0.2
<0.2
<0.2
%FS
TILT REPEATABILITY
<0.005
<0.005
<0.008
<0.01
<0.01
arcdeg
OUTPUT FORMAT
ASCII
ASCII
ASCII
ASCI
ASCII
RS232/USB
CALIBRATION
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
non-volatile
UPDATE RATE
10
10
10
10
10
Hz
SUPPLY
5
5
5
5
5
Vdc
TEMPERATURE
-40 to +85 operational
degC
TEMPERATURE
-55 to +125 storage
degC
UPDATE MODES
continuous and on demand
modes
UPDATE TYPES
programmable scan delay, filter, dumping delay
types
SERIAL LINK
1200-38400 baud, 8 bit, No parity, 1 stop, No flow control
·
All data acquired at room
temperature after corresponding range linear calibration/correction
·
Viscosity of electrolyte may be
altered to accommodate customer’s application requirements.
·
Self powered from RS-232 or USB
ports is available
COMMANDS:
NOT
case sensitive and must end with <CR>.
COMMAND
ARGUMENT
DESCRIPTION
help
<CR>
prints all user commands
ver
<CR>
prints version number on the screen
reboot
<CR>
Restart
ax
<CR>
Restart
baudrate
[1200 – 38400]
set baudrate [19200 default]
go
<CR>
sets temporary continuous mode
auto
[on/off]
Continuous output ON / OFF
h
<CR>
halt continuous mode
lincal
[r/p/on/off]
calibrate/select/activate linear correction
zero
[r/p] [off] set/cancel/selectable
ZERO orientations
zero
[h] [ h off] set/cancel/ retainable HARDIRON ZERO
print
rpt
Select variables for display
refresh
0.1 to 600sec
Select display refresh rate
filter
[1 to 40]
Select filtering coefficient, default 10
s?
Single scan update
selected values, PC mode only
r?
Show Roll
roll angle (arcdeg), PC mode only
p?
Show Pitch
pitch angle (arcdeg), PC mode only
zero ?
Show Zero
all zero offsets
Housing installation procedure:
To install the system you are required to place it flat on a surface and try to level the surface to near null reading in both axes.
Locate the position where you want to install the housing. Remove the cover and secure the housing to the surface with one screw.
Tilt the surface one to two degrees and observe the output of the module on the screen with a go<CR> command in Hyper terminal mode. Try to pivot (slightly rotate) the housing until one of the outputs (cross axis) is equal zero.
Secure the housing with the second ( third and fourth ) screws and close the cover.
At this time the module is properly setup for minimum
cross axis tilt error.
![]() |
ADVANCED ORIENTATION SYSTEMS, Inc. 2525 BRUNSWICK AVE, Suite 205 LINDEN, NJ 07036, USA. Phone: 908-474-9595 Fax: 908-474-9090 sales@aositilt.com http://www.aositilt.com |