When using single option for reading X or Y, the data will be stored in the data file data.txt for future use. You may change the number of points to be stored and the name of the file.
WIRE THE CABLE BETWEEN THE BOARD, POWER SUPPLY AND RS-232 CONNECTOR.
A.pin 1 on board is: PIN 3 ON A 25D CONNECTOR IS PIN 2 ON 9D PIN CONNECTOR.
B.pin 2 on board is: PIN 2 ON A 25D CONNECTOR IS PIN 3 ON 9D PIN CONNECTOR.
C.pin 3 on board is: 9-12 Vdc.
D.pin 4 on board is: PIN 7 ON A 25D CONNECTOR IS PIN 5 ON 9D PIN CONNECTOR and is GND.
THE FOLLOWING IS A LIST OF COMMANDS TO BE USED for the EZ-TILT 1000 ANGLE CONVERSION MODULES WHEN UTILIZING TERMINAL MODE IN WINDOWS OR THROUGH ANY OTHER RS-232 PROGRAM.
| COMMAND | OUTPUT MODULE | DESCRIPTION |
|---|---|---|
| 0 | X X CR | READ X AXIS |
| 1 | X X CR | READ Y AXIS |
| 2 | * | RESET CPU |
| 3 | NOT USED | |
| 4 | NOT USED | |
| 5 | NOT USED | |
| 6 | X X | SPARE READ ADC INPUT |
![]() |
ADVANCED ORIENTATION SYSTEMS, Inc. 2525 Brunswick Ave, Suite 205 LINDEN, NJ 07036, USA. Phone: 908-474-9595 Fax: 908-474-9090 sales@aositilt.com http://www.aositilt.com |