APPLICATION NOTE EZ-TILT-3000-XXX tilt angle conversion module for electrolytic tilt sensors and angle measurement devices.

APPLICATION NOTE: EZ-TILT-3000-XXX



EZ-TILT 3000 are highly advanced and flexible angle conversion modules for single and dual axis tilt measurement applications. EZ-TILT 3000 are able to provide a complete DUAL AXIS angle measurement solution with an ANALOG output.

These miniature SMT modules are available in a WIDE RANGE or HIGH RESOLUTION versions. RATIOMETRIC by design, they can be powered by a unipolar or bipolar supply. Advanced CMOS design guarantees low current consumption, which makes these modules a logical choice for various battery powered applications. As with any other AOSI angle conversion module, you may install the sensor directly on the PCB or remotely.

With proper selection of supply voltage and GAIN settings these modules may be directly interfaced to standard A/D converters or computer I/O data acquisition boards.

SpecificationData/Description/units
Max supply voltage ( VDD - VSS )18 Vdc
Min supply voltage ( VDD - VSS )4.6 Vdc
Current @ Vsupply (mA @ Vdc ) VDD - 1Vdc
Output voltage minVSS + 1Vdc
Response time 10% - 90%40msec
Noise band width 0Hz to 100Hz<1mVdc
Min resistive load on X or Y outputs3Kohm
Min resistive load on Vtemp100Kohm
Min resistive load on Vref100Kohm
R18Offset adjustment for X
R29Offset adjustment for Y
R24Gain adjustment for X
R30Gain adjustment for Y

The offset adjustment is 20% of the supply voltage, and is centered on Vref. For example : for 5Vdc supply, adjustment is +- 0.5Vdc centered on 2.5Vdc.

The gain is independent of the supply. Higher output signal could be achieved with higher supply voltage. For example : 0.3Vdc/arcdeg will require 8 Vdc supply for a tilt range of +/-10 arcdeg.
( I VDD I - I VSS I )volt=(scale factor volt/arcdeg * range arcgeg) + 2volt
Vrefvolt = ( I VDD I - I VSS I ) /2 volt +/-0.2volt
CONNECTOR pin #designation
1Vtemp ( temperature sensors output )
2Vref ( half of the I VDD I - I VSS I ) output 1
3VDD
4X output
5Y output
6VSSNOTE:

Vref can be forced to a voltage. The equivalent input for Vref is a 3.01K resistor in parallel with 22uF cap. Desoldering R21, R28 and C13 will increase input resistance to 100K, and lower the equivalent C to 100pF. Vref should be free of electrical noise.


For industrial applications requiring 4-20ma current output, the EZ-TILT-3000 module can be upgraded with a special current output option. Please select the link below to view specifications for this upgrade: 4-20ma Industrial output upgrade option datasheet.

Specifications may change without notice.


ADVANCED ORIENTATION SYSTEMS, Inc.
2525 Brunswick Ave, Suite 205
LINDEN, NJ 07036, USA.
Phone: 908-474-9595
Fax: 908-474-9090
sales@aositilt.com
http://www.aositilt.com