APPLICATION NOTE EZ-TILT-3000-XXX tilt angle conversion module for electrolytic tilt sensors and angle measurement devices.

APPLICATION NOTE: EZ-TILT-3000-LIN/NULL



EZ-TILT 3000 are highly advanced and flexible angle conversion modules for single and dual axis tilt measurement applications. When using EZ-TILT 3000 with Single Axis tilt sensors, the sensor should be wired to any diagonal of pads in the center of the PCB, with common center electrode of the sensor wired to the pad #5 in the center of the PCB. In this case you will observe valid output on both #4 and #5 connector pins.

These miniature SMT modules are available in a WIDE RANGE or HIGH RESOLUTION versions. RATIOMETRIC by design, they can be powered by a uni-polar or bipolar supply. Advanced CMOS design guarantees low current consumption, which makes these modules a logical choice for various battery powered applications. As with any other AOSI angle conversion module, you may install the sensor directly on the PCB or remotely.

With proper selection of supply voltage and GAIN settings these modules may be directly interfaced to standard A/D converters or computer I/O data acquisition boards.

SpecificationData/Description/units
Max supply voltage ( VDD - VSS )18 Vdc
Min supply voltage ( VDD - VSS )4.6 Vdc
Current @ Vsupply (mA @ Vdc ) VDD - 1Vdc
Output voltage minVSS + 1Vdc
Response time 10% - 90%40msec
Noise band width 0Hz to 100Hz<1mVdc
Min resistive load on X or Y outputs3Kohm
Min resistive load on Vtemp100Kohm
Min resistive load on Vref100Kohm
R18Offset adjustment for X
R29Offset adjustment for Y
R24Gain adjustment for X
R30Gain adjustment for Y

The offset adjustment is 20% of the supply voltage, and is centered on Vref. For example : for 5Vdc supply, adjustment is +- 0.5Vdc centered on 2.5Vdc.

The gain is independent of the supply. Higher output signal could be achieved with higher supply voltage. For example : 0.3Vdc/arcdeg will require 8 Vdc supply for a tilt range of +/-10 arcdeg.
( I VDD I - I VSS I )volt=(scale factor volt/arcdeg * range arcgeg) + 2volt
Vrefvolt = ( I VDD I - I VSS I )/2 volt +/-0.2volt
CONNECTOR pin #designation
1Vtemp ( temperature sensors output )
2Vref ( half of the I VDD I - I VSS I ) output 1
3VDD
4X output
5Y output
6VSS 

NOTE: Vref can be forced to a voltage. The equivalent input for Vref is a 3.01K resistor in parallel with 22uF cap. De-soldering R21, R28 and C13 will increase input resistance to 100K, and lower the equivalent C to 100pF. Vref should be free of electrical noise.


For industrial applications requiring 4-20ma current output, the EZ-TILT-3000 module can be upgraded with a special current output option. Please select the link below to view specifications for this upgrade: 4-20ma Industrial output upgrade option datasheet.

Specifications may change without notice.


ADVANCED ORIENTATION SYSTEMS, Inc.
1901 E. LINDEN AVENUE, Unit 22
LINDEN, NJ 07036, USA.
Phone: 908-474-9595
Fax: 908-474-9090
sales@aositilt.com
http://www.aositilt.com